10.1. General information

The glow plug is installed in each vortex camera. Glow plugs are used at launch of the cold engine. Giving of tension to glow plugs the timer from an engine EBU signal operates.
The control lamp in a combination of devices burns during the work of candles of an incandescence. After switching off of a lamp the engine can be launched. Tension to glow plugs moves within several seconds after inclusion of a control lamp. If after switching off of a lamp the attempt to launch the engine does not become, the timer disconnects tension from incandescence candles to avoid a discharge of the rechargeable battery and an overheat of candles of an incandescence.